Features:
Connects your strain gauge device directly to your computer
Converts your Load Cell etc into an Intelligent Strain Transducer
NEW ! ! - ATEX component approval on CAN bus versions - Ex Na II
Easy mounting via 2 mm screw
Connection via solder holes to either side of PCB
Low profile to fit in very small apertures
Baud rates to 230,400
High speed to 500 readings/second
Lower cost "Industrial Stability" option
±15kV ESD protected
Real mV/V calibration
Extreme noise immunity 5 x heavy industrial level
Transducer calibration
Remote shunt calibration
Very high stability (capable of 6000 Divisions OIML)
Peak and trough recording
Programmable dynamic filter
Wide operating voltage (5.4V - 18V)
DC Excitation for longer cable lengths
Diagnostics LED
ILE Inline Converter Housing now available to house your DCell
Advanced Characteristics:
An Intelligent Strain Transducer
High Performance
3 Year Manufacturer's Warranty
Serial Communications - excellent stability, RS485
Fieldbus connectivity - universal systems compatibility
Direct output in Engineering Units if required
Resolution selectable to 1 part in 400,000
"Plug in and go" sensor - no need for a separate amplifier
No need for an expensive A-to-D Card
Outstanding performance-to-cost ratio
Five-point transducer temperature compensation via comms
Seven-point transducer linearisation via comms
Sensor operation limit alarms
Reverse polarity protected
Continuous auto-zero operation
On-board temperature measurement as option
Optionally, temperature may be measured with an external probe
Ideal for high precision measurement at low cost
Non-expert maintenance
Capable of ATEX Approval
Self diagnostics alerts user to common Strain Gauge faults:
Excitation short-circuits
Input over- or under-range
Cell scaling over- or under-range
System scaling over- or under-range
Temperature over- or under-range
Communication errors
Small package size
Works with most common strain gauge devices
Saves cost and space
All you need to add is a DC power supply
Simple to use
Competitive prices with generous quantity discounts
Ideal for OEM, R&D, Production, QA, QC applications
Can connect up to 254 devices on one RS485 bus
Full CE approval
Options:
Temperature compensation via external sensor
OEM Application Software through Bootloader,
allowing special functions to be programmed via RS485
RS232 - RS485 Converter
Alternative sensitivities (1 - 20 mV/V)
DTemp temperature sensing module
Precision vs Speed of Reading:
Generally, the higher the precision required from an analogue-to-digital system, the slower the speed of conversion to digital format. The D-Cell allows you to select the resolution and speed of reading that you require according to the Table below:
Speed
Readings/sec
(Hz) |
Resolution |
|
DLCH Models
High Stability |
DLCS Models
Industrial Stability |
|
|
ppm |
% of
Full Scale |
Divisions
1 part in... |
ppm |
% of
Full Scale |
|
1 |
400,000 |
2.5 |
0.00025 |
100,000 |
10 |
0.0010 |
|
10 |
120,000 |
8.3 |
0.00083 |
40,000 |
25 |
0.0025 |
|
100 |
50,000 |
20 |
0.00200 |
10,000 |
100 |
0.0100 |
|
500 |
18,000 |
56 |
0.00560 |
5,000 |
200 |
0.0500 |
Choice of Communication Options:
|
RS485: |
ASCII Protocol
MANTRABUS II Protocol
MODBUS Protocol |
|
CAN Versions: |
MantraCAN Protocol
CANOpen Protocol |
Product Order Codes:
| |
High Stability DLCH |
Industrial Stability DLCS |
|
RS485 ASCII Protocol |
DLCHASC |
DLCSASC |
|
RS485 MANTRABUS II Protocol |
DLCHMAN |
DLCSMAN |
|
RS485 Modbus RTU Protocol |
DSLCHMOD |
DLCSMOD |
|
MantraCAN Protocol |
DSLCHCAN |
DLCSCAN |
|
CANOpen Protocol |
DLCHCOP |
DLCSCOP |
Specifications:
| Description |
Units |
High Stability |
Industrial Stability |
| Min |
Typ |
Max |
Min |
Typ |
Max |
| Bridge Excitation: |
VDC |
4.5 |
5 |
5.25 |
4.5 |
5 |
5.25 |
| Bridge Impedence: |
Ohms |
320 |
350 |
5,000 |
320 |
350 |
5,000 |
| Bridge Sensitivity: |
mV/V |
-3 |
- |
+3 |
-3 |
- |
+3 |
| Offset Temperature Stability: |
ppm/°C |
- |
1 |
4 |
- |
5 |
10 |
| Gain Temperature Stability: |
ppm/°C |
- |
3 |
5 |
- |
30 |
50 |
| Offset Stability With Time: |
% FR |
- |
0.002 |
0.008 |
- |
0.0035 |
0.016 |
| Gain Stability With Time: |
ppm of FR/1st Year |
- |
- |
30 |
- |
- |
300 |
| Nonlinearity: |
% FR |
- |
0.0005 |
0.0025 |
- |
0.0005 |
0.0025 |
| Internal Resolution: |
Counts/Divisions |
- |
16 Million |
- |
- |
16 Million |
- |
|
Resolution
@ 1 Hz: |
Counts/Divisions over 100s |
- |
400,000 |
- |
- |
100,000 |
- |
Resolution
@ 10 Hz: |
Counts/Divisions over 100s |
- |
120,000 |
- |
- |
40,000 |
- |
Resolution
@ 100 Hz: |
Counts/Divisions over 100s |
- |
50,000 |
- |
- |
10,000 |
- |
Resolution
@ 500 Hz: |
Counts/Divisions over 100s |
- |
18,000 |
- |
- |
5,000 |
- |
|
Optional:
Temperature Measurement Resolution |
°C |
- |
0.1 |
- |
- |
Not available |
- |
|
Optional:
Temperature Measurement Accuracy |
°C |
- |
1 |
- |
- |
Not available |
- |
| Power Supply Voltage: |
VDC |
5.4 |
12 |
18 |
5.4 |
12 |
18 |
| Power Supply Noise/Ripple: |
|
- |
- |
100 |
- |
- |
100 |
| Power Supply Current (350R Bridge): |
mA |
- |
45 |
60 |
- |
45 |
60 |
| Power @ 10V Supply (350R Bridge): |
mW |
- |
350 |
- |
- |
350 |
- |
| Sensor Impedence: |
Ohms |
320 |
350 |
5,000 |
320 |
350 |
5,000 |
|
Excitation System: |
- |
- |
4-wire |
- |
- |
4-wire |
- |
| Operating Temperature Range: |
°C |
-40 |
- |
+85 |
-40 |
- |
+85 |
| Operating Temperature Range for OIML 6000d: |
°C |
-10 |
- |
+55 |
- |
- |
- |
| Storage Temperature: |
°C |
-40 |
- |
+85 |
-40 |
- |
+85 |
| Humidity: |
% RH Non-condensing |
0 |
- |
95 |
0 |
- |
95 |
| RS485 Data Rate: |
Baud |
2,400 |
- |
230,400 |
2,400 |
- |
230,400 |
| CAN Bit Rate: |
Bits/s |
10k |
- |
1M |
10k |
- |
1M |
| Package: |
PCB with metal shield, IP40 protected |
| Dimensions: |
RS485 Versions: Diameter 20 mm x Height 5 mm
CAN Versions: Diameter 20 mm x Height 10.5 mm

For 6-wire strain gauges, connect +SENSE to +EXC and -SENSE to -EXC
|
| Environmental Approvals: |
EMC Directive 89/336/EEC
EMC Emissions
EN 50 081-1 :1992 (Light Industrial)
EN 50 081-2 :1992 (Heavy Industrial)
EMC Immunity
EN 50 082-1 :1992 (Light Industrial)
(RF Field Test 0.001% FS over 30 to 500MHz)
EN 50 082-2 :1992 (Heavy Industrial)
(RF Field Test 0.005% FS over 30 to 500MHz)
Low Voltage Directive 73/23/EEC amended by 93/68/EEC
IEC 1010-1 :1990
BSEN 610101 :1993 |
Buy securely OnLine now using

Please select the appropriate shipping method
then click "Add To Cart"
You can change the quantities on the "Cart" page
HIGH STABILITY OPTIONS
WITH RS485 OR CAN COMMUNICATIONS
INDUSTRIAL STABILITY OPTIONS
WITH RS485 OR CAN COMMUNICATIONS
EASY-CONNECT MODULES
& ACCESSORIES
Please contact us for quotations for quantities etc
|

DCell Miniature Digital Strain Gauge Conditioning Amplifier
shown with DTemp option

DCSLOG24 Freeware Software allows up to 24 DCell and/or DSC channels to be displayed and logged simultaneously

DS485DIS Digital RS485 Display Module for up to 8 DCell or DSC systems
DSCUSB USB version of the DSC, with DSCUSB Toolkit software
Buy securely OnLine now using

Other products that might be of interest:
ADP15 Process Controllers
ADW15 Weighing Controllers
ALA5 ATEX Strain Gauge Amp
DS485DIS Digital Display Module
DSC Digital Strain Card
DSCUSB DSC with USB comms
DSJ Easy-connect module
ICA InCell Analogue Amps
ILE In Line Housing
JBA
LCA15 Surface Mount controllers
LVDT Amplifier
PSD Hand-Held Load Display
T24 Radio telemetry system
RCA15 Rack mount system
RUA Rack mount system
SerialDis Digital Display
SGA Analogue strain gauge Amp
SMP Surface mount controller
SMW Weighing controller
UAB Rack mount system
VisualLink Rapid development software
|